Coolside

Product detail

Coolside Door (CW)
This unit is the most innovative and efficient system for managing Hot spots inside data centers, in other words, HIGH DENSITY racks up to and over 40 kW/m2 per rack. The Cooling door unit is housed at the rear of the rack and is managed by a DYNAMIC system, especially designed to handle the rack exhaust air, which SELF-ADAPTS to rack requirements. MAIN CARATTERISTICS – New generationEC fans – 42U / 48U racks adapdability – Can be supplied with with rack – Dinamic control of Air stratification – Configuration R (N+1) and T – Integration into DUAL CIRCUIT, FREECOOLING + BACK UP system – Dehumidification Less Management. WORKING MODE This unit is to be considered both as a stand alone cooling unit for the exhaust air of the single rack in the small data center as a system for managing Hot spots in large data center for integration of hot and cold aisle or compartization structures. While the cooling of RACK is delegated to the perimetral conditioning units that provide cold air 18-20° C in the cold aisle, this cooling door handles rack at higher thermal load (called HOT SPOTS) generally due to the use of modern blade servers.
Coolside DX
The indoor vertical air conditioning unit RACK COOLER is an effective management system of the Hot Spots in the data center, ensuring low energy consumption and usage possibilities even under extremely high loads for HIGH DENSITY rack ´up and over 40 kW/m2 rack. The use of EC fan systems, featuring last-generation electronic-switching brushless motors, assures excellent performance and low consumption. Available as standard with the dynamic management of N +1 EC fans to optimize consumption and redundancy of the cooling system. Coupled with outdoor condensing unit air-cooled type with axial-flow fans, fitted with INVERTER-DRIVEN HERMETIC SCROLL compressor for operation on R410A refrigerant, available on versions BASIC and LT for low external temperature.
Coolside DF
The indoor vertical air conditioning units RACK COOLER is an effective management system of the Hot Spots in the data center, ensuring low energy consumption and usage possibilities even under extremely high loads for HIGH DENSITY rack ´up and over 40 kW/m2 rack. The use of EC fan systems, featuring last-generation electronic-switching brushless motors, assures excellent performance and low consumption. The Rack Cooler Dual Fluid unit provides redundancy in cooling capacity also in emergency situations: to be connected to an external chiller for primary chilled water circuit, and to condensing unit i-HCAT for the secondary or back up circuit in direct expansion type. The condensing unit air-cooled type with axial-flow fans, fitted with INVERTER-DRIVEN HERMETIC SCROLL compressor for operation on R410A refrigerant, mounted on rubber vibration dampers, complete with oil charge, supplied with oil separator to ensure correct lubrication even at minimum speed, and fitted with thermal protector; available on BASIC versions and LT for low external temperature.
Coolside FC
The indoor vertical air conditioning units RACK COOLER is an effective management system of the Hot Spots in the data center, ensuring low energy consumption and usage possibilities even under extremely high loads for HIGH DENSITY rack up and over 40 kW/m2 rack.The use of EC fan systems, featuring last-generation electronic-switching brushless motors, assures excellent performance and low consumption. The Rack Cooler, coupled with the condensig water unit, combines the direct expansion system with the use of indirect free cooling water to ensure the cooling capacity required by the server with the maximum energy savings. The works in free cooling mode when the outside temperature permits using outdoor air as a source of indirect cooling, allowing the simultaneous operation between direct expansion system and water to maximize efficiency. For an easy integration in the plant, the water condensing unit fitted with plate heat exchanger, is equipped with dry cooler axial fans, circulation pump and expansion vessel. Fitted with INVERTER-DRIVEN HERMETIC SCROLL compressor for operation on R410A refrigerant, mounted on rubber vibration dampers, complete with oil charge, supplied with oil separator to ensure correct lubrication even at minimum speed, and fitted with thermal protector.

 

Scroll to Top